 Copyright RetroZone inc.2012 | 
 
 
				The UZC Zoning System  
 
 
				
				Compatible with all HVAC systems with up to 4 stages of heat and 
				two stages of cool. 
				The main panel is a 4 zone configuration and is expanded 2 zones 
				at a time. EWC will package the UZC in a 6, 8, or 10 zone 
				configuration. For larger systems consult the factory. 
				The UZC4 Universal Zone Control System allows you to easily 
				upgrade an inefficient single zone HVAC system, into an 
				Automated, Multi-zone, Energy saving, Comfort producing, Safety 
				Minded, HVAC system. With Superior design, Intuitive firmware, 
				Building Code Compliant support, Simple setup options, and Easy 
				to understand wiring, the UZC4 Zoning system is the 
				Designer/Contractors dream. Combined with Patented EWC motorized 
				dampers and practically any Off-the-shelf Conventional or Heat 
				Pump style Thermostats, EWC has set a New Industry Standard in 
				Large Residential and Commercial HVAC Air Zoning Systems. 
				The main module controls four air zones using 24 vac motorized 
				air dampers and may be expanded up to 20 zones, using ZXM2 
				Expansion Modules. The UZC4 will Control 2, 3 & 4 stage 
				Conventional, GeoThermal or Dual Fuel Heat pumps, without the 
				need for dual fuel kits. Also single or multi-stage Gas, Oil, & 
				Hydronic HVAC systems, with single or two stage cooling and 
				Constant or Variable speed fan systems. It is compatible with 
				most off the shelf 1 or 2 stage Conventional Heat/Cool or Heat 
				Pump Thermostats. All Mechanical, Digital/Electronic, Dual Mode, 
				and Internet Compatible Thermostats that operate on 24vac. 
				Battery powered or Power robbing thermostats that draw less than 
				20 ma of current are also accepted. Zone 1 will accept One Zone 
				Mode, Carbon Dioxide Safety and Auxiliary/Dehumidify mode 
				inputs. 
				The UZC4 Zone system features automatic changeover from any 
				thermostat allowing for individual zone comfort from the HVAC 
				system. The STATUS LED pulses as a steady heart beat to indicate 
				active Microprocessor status. On board LED’s will illuminate to 
				indicate system status, HVAC system mode, and active / inactive 
				zone identification. See page 21 For details. Damper 1 thru 
				Damper 20 LEDs will indicate which zone dampers are demanded to 
				energize Open or Closed. All modules operate on 24vac power 
				supplied from a separate transformer. A single 40va transformer 
				can power up to 4 zones, with a total of 8 Genuine EWC ND or URD 
				dampers directly connected. 
				The UZC has the ability to inhibit the second, third, and fourth 
				stages of heating during mild outdoor temperatures. The UZC can 
				also inhibit second, third, and fourth stages of heating if less 
				than half of the total number of zones are activated. 
				The UZC4 has too many options and features to list here.  Please 
				view our tech bulletin for details. 
				
				Click here for the tech bulletin (Acrobat 
				format, approx. 2.8 MB) 
				Note: The UZC3 has been superseded by the UZC4.  If you still 
				need a tech bulletin for the UZC3 please Click 
				here(Acrobat format, approx. 5.4 MB) 
 |